What causes cloudy, soft, or small ice cubes?
Ice quality issues often indicate water system or refrigeration problems: cloudy ice suggests poor water quality or mineral content; soft ice indicates inadequate freeze cycle time or refrigerant issues; small or misshapen cubes typically point to low water flow, scale buildup on evaporator plates, or refrigerant problems. All of these issues affect the safety and quality of ice used in beverages and food service.
What are the critical food safety temperatures for kitchen equipment?
Critical food safety temperatures: Cold holding — 40°F (4°C) or below for refrigeration; freezer 0°F (-18°C) or below. Hot holding — 140°F (60°C) or above for steam tables and food warmers. Cooking temperatures vary by food type (145°F-165°F). Dishwasher final rinse — 180°F (82°C) for high-temp machines. Any equipment consistently failing to maintain these temperatures is both a safety risk and a health code violation.
What are the signs of a failing compressor?
Signs of compressor problems: unit not reaching temperature despite running constantly, compressor making loud knocking or grinding sounds, compressor starting and stopping rapidly (short cycling), compressor not starting at all, or high pressure shutdowns. Compressor failure is typically the most expensive refrigeration repair. Early diagnosis can sometimes allow for less costly repairs — don't wait if you hear unusual compressor noises.