How often should walk-in cooler door gaskets be replaced?
Walk-in door gaskets typically last 2-4 years and should be inspected every 6 months. Signs of failing gaskets: visible tears or cracks, frost buildup near the door frame, condensation on the door frame, noticeably warmer temperatures near the door, or the door not staying closed. A failing gasket forces the compressor to work harder, increasing energy costs and reducing equipment life.
What are the signs of a failing compressor?
Signs of compressor problems: unit not reaching temperature despite running constantly, compressor making loud knocking or grinding sounds, compressor starting and stopping rapidly (short cycling), compressor not starting at all, or high pressure shutdowns. Compressor failure is typically the most expensive refrigeration repair. Early diagnosis can sometimes allow for less costly repairs — don't wait if you hear unusual compressor noises.
My walk-in cooler temperature is rising. What should I do first?
1) Check if the condenser unit is running. 2) Inspect condenser coils for dirt and debris — blocked coils are a common cause. 3) Ensure walk-in door gaskets are sealing properly. 4) Check if evaporator fan is running. 5) Look for ice buildup on evaporator coils (defrost system failure). If temperature is rising significantly, move temperature-sensitive inventory and call a technician immediately — this is an emergency situation.