What does an NFPA 96 compliant hood cleaning include?
A compliant hood cleaning includes: complete degreasing of the hood canopy, all grease filters, the entire ductwork system from hood to exhaust fan discharge, and the exhaust fan and housing. Areas that cannot be thoroughly cleaned must be documented. Cleaning must be performed by a qualified company and documented with service report and before/after photos. The technician should leave a dated sticker on the equipment and provide a compliance certificate.
My walk-in cooler temperature is rising. What should I do first?
1) Check if the condenser unit is running. 2) Inspect condenser coils for dirt and debris — blocked coils are a common cause. 3) Ensure walk-in door gaskets are sealing properly. 4) Check if evaporator fan is running. 5) Look for ice buildup on evaporator coils (defrost system failure). If temperature is rising significantly, move temperature-sensitive inventory and call a technician immediately — this is an emergency situation.
What temperature should commercial refrigerators maintain?
Commercial refrigerators must maintain 40°F (4°C) or below for food safety compliance. Walk-in freezers should be at 0°F (-18°C) or below. Many food safety programs require refrigerators to run at 35-38°F for proper margin. If your unit struggles to maintain proper temperature, especially during busy service periods or in hot kitchen environments, call a technician — compressor capacity or refrigerant levels may be the issue.